Duplex Pump Output Q (bbl/stroke) and q (bpm)
The mud pump output is a crucial parameter in drilling operations. It represents the volume of drilling fluid (mud) pumped per stroke.
Different correlations are used to calculate outputs for Duplex and Triplex pumps.
Reference: www.drillingmanual.com
Correlations
- Pump Output Q
- Pump Output q
Input Parameters
Name | Input Value - Unit | Converted Value | Validity | Link to Calculation Page | |||
---|---|---|---|---|---|---|---|
Pump Liner Diameter | 5.5 | in | |||||
Pump Rod Diameter | 2 | in | |||||
Stroke Length | 14 | in | |||||
Stroke Per Minute | 50 | stroke/min | |||||
Pump Volumetric Efficiency | 100 | % | |||||
CALCULATE | |||||||
Results | |||||||
Correlation | Calculated Value | Warnings | Remarks | ||||
Pump Output Q | 0.1281 | bbl/stroke | |||||
Pump Output q | 6.4035 | bbl/min - bpm |