Stroke per Minute (SPM) Required for Target Annular Velocity

The annular velocity is one of two major variables in the process of cleaning solids ( drill cuttings) from the wellbore.

It is important to monitor annular velocity to ensure that the hole is being properly cleaned of cuttings, cavings and other debris while avoiding erosion of the borehole wall.

Correlations

  • Pump SPM Required

Input Parameters

NameInput Value - UnitConverted ValueValidityLink to Calculation Page
Annular Velocity

120

ft/min

Well Annular Velocity
Annular Capacity

0.1261

bbl/ft

Well Annular Capacity Between Casing or Hole and Pipes
Pump Output

0.136

bbl/stroke

Duplex Pump Output Q (bbl/stroke) and q (bpm)- Triplex Pump Output Q (bbl/stroke) and q (bpm)

CALCULATE

Results

CorrelationCalculated ValueWarningsRemarks
Pump SPM Required111.26stroke/min